This function opens a new connection to a target machine with access to SNMP data for the provided MIB. It returns a handle required by all other BDL SNMP extension functions. It supports both SNMPv1/2c and SNMP3.
Snmp.bdh
SnmpOpenConnectionEx( in sMachine : string,
in sMib : string,
in sVersion : string,
in sCommunity : string optional,
in sAuthProtocol : string optional,
in sPrivProtocol : string optional,
in sAuthPassword : string optional,
in sPrivPassword : string optional,
in sSecurityName : string optional,
in sSecurityLevel : string optional,
in sSecurityModel : string optional,
in sContextName : string optional,
in sContextEngineID : string optional ): number;
Handle for open connection (0 on failure)
| Parameter | Description |
|---|---|
| sMachine | Specifies target machine and port on which the smnp server is listening. |
| sMib | Specifies the name of the MIB. |
| sVersion | Specifies the version of the SNMP data. |
| sCommunity | Specifies the community of the SNMP data. |
| sAuthProtocol | Specifies the Authentication protocol of the SNMP data. (Version 3) |
| sPrivProtocol | Specifies the Privacy Protocol of the SNMP data. (Version 3) |
| sAuthPassword | Specifies the Authentication Password of the SNMP data. (Version 3) |
| sPrivPassword | Specifies the Privacy Password of the SNMP data. (Version 3) |
| sSecurityName | Specifies the Security Name of the SNMP data. (Version 3) |
| sSecurityLevel | Specifies the Security Level of the SNMP data. (Version 3) |
| sSecurityModel | Specifies the Security Model of the SNMP data. (Version 3) |
| sContextName | Specifies the Context Name of the SNMP data. (Version 3) |
| sContextEngineID | Specifies the Context Engine ID of the SNMP data. (Version 3) |
benchmark Collect
use "pdce.bdh"
use "snmp.bdh"
var
measureMachine : string;
measureMachineServer : string;
measureMachinePort : string;
const
MEASURE_VERSION := "V3";
MEASURE_NAME := "System/Services";
MEASURE_MIB := "SNMPv2-MIB";
MEASURE_OID_NAME := "system.sysServices";
MEASURE_PRIVPWD := "pwd12345678";
MEASURE_AUTHPWD := "pwd12345678";
MEASURE_SECURITY_LEVEL := "3";
MEASURE_SECURITY_MODEL := "3";
MEASURE_SECURITY_NAME := "testuser";
MEASURE_CONTEXT_NAME := "";
MEASURE_CONTEXT_ENGINE_ID := "";
MEASURE_AUTH_PROTOCOL := "MD5";
MEASURE_PRIV_PROTOCOL := "DES";
var
nInterval : number;
hClient1 : number;
hMeasure1 : number;
sKey1 : string(1024);
dcluser
user
Collect
transactions
NoTRT_TStartup : begin;
NoTRT_TCollect : 5;
NoTRT_TEnd : end;
dclfunc
function PdceGetSnmpKey(sKey : string;
sMachine : string;
sMib : string;
sAuthProtocol : string;
sPrivProtocol : string;
sAuthPassword : string;
sPrivPassword : string;
sSecurityName : string;
sSecurityLevel : string;
sSecurityModel : string;
sContextName : string;
sContextEngineID : string;
sVersion : string;
sOidName : string;
nInstance : number optional) : boolean
var
sMibOid : string(1024);
sInstanceOid : string(1024);
sValue : string(1024);
sOid,sOid_old : string(1024);
hSnmp : number; // SNMP connection handle
sKey_old : string(1024);
begin
hSnmp := SnmpOpenConnectionEx(sMachine, sMib, sVersion, "",
sAuthProtocol, sPrivProtocol,
sAuthPassword, sPrivPassword,
sSecurityName, sSecurityLevel, sSecurityModel,
sContextName, sContextEngineID);
if ( hSnmp <> 0 ) then
if not SnmpGetMibOid(hSnmp, sOidName, sMibOid) then
RepMessage("SnmpGetMibOid failed: "+sMibOid,SEVERITY_ERROR);
end;
Print("OID for " + sOidName + " : " + sMibOid);
SnmpGetFirstInstanceOid(hSnmp, sMibOid, sInstanceOid);
//old version
Print("InstanceOid: " + sInstanceOid);
sOid_old := sMibOid + "." + sInstanceOid;
Print("Old Oid: " + sOid_old);
sOid := SnmpGetValueOid(hSnmp, MEASURE_OID_NAME, "72", MEASURE_OID_NAME);
Print("OID with first instance: " + sOid);
if Stricmp(sOid,sOid_old) <> 0 then
RepMessage("SnmpGetValueOid failed: "+sOid,SEVERITY_ERROR);
end;
if SnmpGetValue(hSnmp, sOid, sValue) then
Print("Value: " + sValue);
end;
sKey := SnmpCreatePdceKeyEx(sOid, measureMachine, sVersion, "",
sAuthProtocol, sPrivProtocol,
sAuthPassword, sPrivPassword,
sSecurityName, sSecurityLevel, sSecurityModel,
sContextName, sContextEngineID);
print(sKey);
// manually added - no next interface available
if SnmpGetNextInstanceOid(hSnmp, sInstanceOid) then
print(sInstanceOid);
else
RepMessage("SnmpGetNextInstanceOid didn't find a next instance. "+sInstanceOid,SEVERITY_WARNING);
end;
PdceGetSnmpKey := true;
SnmpCloseConnection( hSnmp )
end;
PdceGetSnmpKey := false;
end PdceGetSnmpKey;
dcltrans
transaction NoTRT_TStartup
begin
AttributeGetString("SNMPTestServer", measureMachineServer);
AttributeGetString("SNMPTestServerPort", measureMachinePort);
measureMachine := measureMachineServer+":"+measureMachinePort;
print(measureMachine);
PdceGetSnmpKey( sKey1, measureMachine, MEASURE_MIB, MEASURE_AUTH_PROTOCOL, MEASURE_PRIV_PROTOCOL,
MEASURE_AUTHPWD, MEASURE_PRIVPWD,
MEASURE_SECURITY_NAME, MEASURE_SECURITY_LEVEL, MEASURE_SECURITY_MODEL,
MEASURE_CONTEXT_NAME, MEASURE_CONTEXT_ENGINE_ID, MEASURE_VERSION, MEASURE_OID_NAME);
PdceStartUp();
PdceRegisterClient(hClient1, nInterval);
PdceAddMeasure(hClient1, MEASURE_NAME, sKey1, hMeasure1);
Wait(float(2*nInterval));
end NoTRT_TStartup;
transaction NoTRT_TCollect
var
fLastValue, fSum, fMin, fMax, fAvg, fStDev : float;
uTimeStamp, uStatus : number;
begin
PdceGetMeasureValue(hMeasure1, MEASURE_NAME);
if (GetWorkloadModel() <> WORKLOAD_MONITORING) then
Wait(float(nInterval));
end;
if PdceMeasureQueryValue(hMeasure1, fLastValue, fSum, fMin, fMax, fAvg, fStDev, uTimeStamp, uStatus) then
Print("Query value: " + String(fLastValue) );
end;
end NoTRT_TCollect;
transaction NoTRT_TEnd
begin
PdceMeasureUnSubscribe(hMeasure1);
PdceClientUnRegister(hClient1);
PdceCleanUp();